P0030, P0032 - Oxygen Sensor Heater Circuit
P0030, P0032, Oxygen Sensor Heater Circuit - Bank 1 Sensor 1 - Fault Code - CM8; CR8; CS8; DP5; DR5; DS5; HG8; HJ8; HK8; HL8; LG1; LGX; LL1; PB1; PJ1; PJZ; PM1; PR1; PRC; PS1; PSC; PX1; PXC; PY1; PYC; YE1; YF1; YM1; YN1
Fault Code | Possible cause | Action |
---|---|---|
P0030 | Oxygen sensor heater open circuit or short to ground - bank 1 sensor 1 | View and note 'freeze-frame' data if available. View and note 'sensor' data. Make sure sensor connector is secure. Disconnect engine ECM and proceed to pinpoint test 1: |
P0032 | Oxygen sensor heater short circuit to battery positive - bank 1 sensor 1 |
Subheading - Pinpoint Test
Pinpoint Tests
P0030, P0032, Oxygen Sensor Heater Circuit - Bank 1 Sensor 1 - Pinpoint Test - PB1, PJ1, L*1, PV1
Test | Result | Action | |
---|---|---|---|
1 | Check cable and terminal integrity: - Engine ECM pin A08 - EMS relay pin 5 | OK | Disconnect oxygen sensors and proceed to test 2 |
Faulty | Rectify fault, proceed to test 5 | ||
2 | Check cable for short circuit: - Engine ECM pin A08 to ground | OK | Proceed to test 3 |
Short circuit | Locate and rectify wiring fault, proceed to test 4 | ||
3 | Check cable continuity: - Engine ECM pin A08 to oxygen sensor pin 4 - Engine ECM pin C22 to oxygen sensor pin 3 | OK | Proceed to test 4 |
Open circuit | Locate and rectify wiring fault, proceed to test 4 | ||
4 | Check cable for short circuit: - Engine ECM pin C22 to Engine ECM pin A08 | OK | Renew oxygen sensor, proceed to test 5 |
Short circuit | Locate and rectify wiring fault, proceed to test 5 | ||
5 | Reconnect harness, clear fault code and run engine. Check adaption status. | OK | Action complete - quit test |
Fault still present | Contact Triumph service |
Subheading - Circuit Diagram
Circuit Diagram
P0030, P0032, P0053, P0134, P0171, P0172 Oxygen Sensor Heater Circuit - Bank 1 Sensor 1 - Circuit Diagram_LG1; LGX; LL1
|