C1302 - Heated Grips
C1302 - Heated Grips - Fault - LG1; LGX; LJ2; LK2; LL1
Fault Code | Possible Cause | Action |
---|---|---|
C1302 | Heated grip current is above or below threshold. | View and note diagnostic tool 'freeze frame' data if available. Proceed to pinpoint test 1. |
Subheading - Pinpoint Test
Pinpoint Tests
C1302 - Heated Grips - Pinpoint Test - LG1; LGX
Test | Result | Action | |
---|---|---|---|
1 | Check the heated grips and instruments are connected | OK | Proceed to test 2 |
Faulty | Rectify fault, proceed to test 4 | ||
2 | Check the harness for short circuit: - Instruments pin 6 to Ground | OK | Proceed to test 3 |
Short circuit | Locate and rectify wiring fault, proceed to test 4 | ||
3 | Check cable continuity: - Instruments pin 6 to left heated grip pin 1 - Instruments pin 6 to right heated grip pin 1 | OK | Contact Triumph service |
Faulty | Locate and rectify wiring fault, proceed to test 4 | ||
4 | Reconnect harness, clear fault code and run engine | OK | Action complete - quit test |
Fault still present | Contact Triumph service |
Subheading - Circuit Diagram
Circuit Diagram
C1302 - Heated Grips - Circuit Diagram - LG1; LGX
|